Global-specialties PB-507 - Manual User Manual

Browse online or download User Manual for Equipment Global-specialties PB-507 - Manual. Global Specialties PB-507 - Manual User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Electronic Design Workstation

1 PB-507 Advanced Analog & Digital Electronic Design Workstation Instruction M

Page 2

10 Frequency knob: changes the value of frequency between 0.1 Hz and 1.000MHz. Level knob: changes the value of the level in the range between 0.1

Page 3 - 2 ABOUT GLOBAL SPECIALTIES

11 • 100.0 Hz - 999.9 Hz • 1.000 KHz – 9.999 KHz • 10.00 KHz – 99.99 KHz • 100.0 KHz – 999.9 KHz • 1 MHz. By pressing Range Up button the freq

Page 4 - TABLE OF CONTENTS

12 Waveform The Function button can be used to select the output function in the following order: - Sine - Triangle - Square - Sine - The current

Page 5 - 3 SPECIFICATIONS

13 Figure 4 Changing the parameters Frequency, Level See description from function generator. The same rules are applied for the pulse generator

Page 6 - 4 INTRO DUCTIO N

14 Figure 5 Unipolar/Bipolar button: The type of the input signal can be changed anytime by pressing the Unipolar/Bipolar button. Description The

Page 7 - 5 START UP

15 Figure 6 The following information is displayed in the counter panel: • The measured frequency and the corresponding period • The type of the

Page 8 - Figure 1

16 Figure 8 Changing the parameters +V, -V Turn the +V knob to change the +V value. Turn the –V knob to change the –V value. The underscored digit

Page 9

17 Figure 9 Description PB-507 provides two open-collector output pulsers, each with 1 normally-open (NO) and 1 normally-closed (NC) output. When t

Page 10 - • 10.0 Hz - 99. 9 Hz

18 Figure 10 Description PB-507 provides 8 logic debounced outputs with 2 user selectable logic families: CMOS and TTL. Each of the logic switches c

Page 11

19 Figure 12 Description • Eight bicolor LEDs (b7…b0) are used to indicate logic high (red) or low (green) for eight digital inputs. • The TTL o

Page 12 - 6.2 Pulse Generator

2 1 FEATURES & APPLICATIONS The PB-507 Advanced Analog & Digital Electronic Design Workstation is a versatile electronics trainer used in al

Page 13 - 6.3 Frequency counter

20 • MEMORY mode detects single shot events and holds indication until Pulse/Mem switch is toggled. • The TTL or CMOS input switching levels can b

Page 14 - Figure 5

21 0000 0001 0010 0011 0100 0101 0110 0111 1000 1001 1010 1011 1100 1101 1110 1111 Table 1 7 MENU SYSTEM This section describes the

Page 15

22 7.1 Configuration menu Table 2 shows the Configuration menu. First level Second level Third level Description Back Go Back to the PB-507 main

Page 16 - Figure 8

23 Table 2 In the Configuration menu the current setting is displayed between “[ ]” brackets for the following settings: Counter mode (AUTO or MAN),

Page 17

24 7.1.3 Security This feature allows you to enter a security code to prevent accidental or unauthorized calibrations or firmware updates of the PB-

Page 18 - 6.7 SPDT switches

25 • Attach power and turn on the instrument.

Page 19 - Figure 13

26 • While the jumper is applied, the device is unsecured. Enter a new security code as described in section Secure the PB-507 Trainer, and record t

Page 20 - 6.10 Seven segment displays

27 In the following table is summarized the factory default settings of the PB-507 Trainer: Parameter Factory setting Function generator Frequency

Page 21 - 7 MENU SYSTEM

28 Note: If the PB-507 Trainer was previously unsecured, loading the default configuration will secure the device with the last saved security code.

Page 22 - 7.1 Configuration menu

29 The following settings are saved: • Function generator: frequency, level, waveform, output On/Off, TTL On/Off • Pulse generator: frequency, lev

Page 23 - 7.1.2 Power-on setting

3 2 ABOUT GLOBAL SPECIALTIES Since 1973, Global Specialties has been the recognized leader in innovative electronics training solutions for educatio

Page 24 - 7.1.3 Security

30 7.3 Service menu The Table 5 shows the Service menu. First level Second level Description Back Go Back to the PB-507 main menu Calibration Func

Page 25

31 • The digit displayed in white type inside a black box indicates the active number. • Use the Level knob from the Function generator module to

Page 26 - • Reassemble instrument

32 b. Two 4 digit numbers are shown on the display. Adjust the numbers until the oscilloscope indicates the closest value to 1.0Vpp of the sine signa

Page 27 - Table 3

33 Figure 21 b. Two 4 digit numbers are shown on the display. Adjust the numbers until the oscilloscope indicates the closest value to 10.0Vpp of t

Page 28

34 b. Two 4 digit numbers are shown on the display. Adjust the numbers until the oscilloscope indicates the closest value to 1.0Vpp of the square sig

Page 29 - 7.2.2 State name

35 Figure 26 b. A 4 digit number is shown on the display. Adjust the number until high duration of the TTL signal is the closest value to 500 micr

Page 30 - 8 CALIBRATION

36 Figure 27 c. Adjust the number until the DMM indicates the closest value to 15V. d. Press the OK soft key to finish this step. The message “Step

Page 31 - 8.1.2 Step 2

37 b. Adjust the number until high duration of the TTL signal is the closest value to 100 microsecond. c. Press the OK soft key to finish this step.

Page 32 - 8.1.5 Step 5

38 Figure 31 c. Adjust the number until the DMM indicates the closest value to 0V. d. Press the OK soft key to finish this step. The message “Step

Page 33 - 8.1.7 Step 7

39 8.3.4 Step 4 a. PB-507 will display: Figure 34 b. Adjust the number until the DMM indicates the closest value to -20V. c. Press the OK soft ke

Page 34 - 8.1.10 Step 10

4 TABLE OF CONTENTS 1 FEATURES & APPLICATIONS ... 2 2 ABOUT GLOBAL SPECIALTI

Page 35 - • Digital multimeter (DMM)

40 • Page scrolling set to JUMP • Default configuration loaded • Power-on option set to default • Power-on option set to last save • State store

Page 36 - 8.2.3 Step 3

41 If more than 15 errors have occurred, the last error stored in the queue (the most recent error) is replaced with “Queue overflow”. No additional

Page 37

42 PC through USB cable. This will cause Windows to prompt for device driver installation. The following information messages may appear on PB-507

Page 38 - 8.3.3 Step 3

43 7. Once the update starts “Download progress” and “Do not turn off the power” messages will appear on display. 8. The update process takes app

Page 39 - 8.3.4 Step 4

44 Global Specialties reserves the right to discontinue models, change specifications, price or design of this device at any time without notice and

Page 40

5 8.3 DC Power supplies calibration ... 37 8.3.1 Step 1 ...

Page 41 - 10 COMPUTER INTERFACE

6 TTL/CMOS compatible Logic Probe Logic Switches (8) Individual Logic Switches Speaker 0.25W, 8Ω Debounced Pushbuttons (2) Open Collector Output P

Page 42 - 10.1 Firmware update

7 The PB-507 has a powerful 1 MHz bandwidth Function Generator with sine, triangle, and square wave output for analog circuits. A Pulse Generator ope

Page 43 - 800-572-1028

8 Figure 1 A power-on self test occurs automatically whenever you turn on the PB-507 Trainer. If the self test passed, the “No errors found” messag

Page 44

9 6.1 Function Generator Front-panel controls Figure 2 shows the Function Generator and Pulse Generator controls on the front panel of the trainer